NT & NQ Transformers and Transformer Rectifiers

NT & NQ Transformers and Transformer Rectifiers

NT66XX Transformers

Transformer-low power-T/J hybrid units for relay and SSI signalling systems 650V/230V/110V/50Vd.c.

Signalling transformers provide the interface between a 650V or 230V power system and a 110V signalling system. Outputs include multiple 110V / 135Va.c. and 50Vd.c. for signalling or 230V for telecoms, all depending on part number chosen.

The transformers comply with NR/L2/SIG/30007 and allow system compliance with Electricity at Works Regulations and NR/SP/ELP/27243.

They provide 8kV minimum impulse withstand voltage in compliance with BS7671 to provide additional protection against ground potential rise in areas with d.c. or a.c. traction systems.

Table 1

  Input Output  
      Output Power VA (per output)  
Part no. KG Voltage V
(1 phase
unless shown)
Fuse A (note 3) Isolated
Windings
ac & dc
Voltage V
(note 5)
Main Taps
(note 1)
135v Tap 50V dc (note 4) Total VA (note 5) Max Fuse
(short CCT)
A (note 2)
PADS
Catalogue Number
NT6600 9 110 4 1 110,135 150/100 50 150 5/2  
NT6610 11.75 650 2 2 110,135
50V d.c
400/350 50
200
500 15/2
10
086/045844
NT6611 11.75 230 4 2 110,135
50V d.c
400/350 50
200
500 15/2
10
 
NT6612 11.75 650 2 1 110 500     500 15 086/045838
NT6620 22.5 650 4 3 110,135
110,135
50V d.c
425/375
425/375
50
50
150 1000 15/2
15/2
10
086/045845
NT6621 22.5 230 10 3 110,135 110,135 50V d.c 425/375
425/375
50
50
150 1000 15/215/210  
NT6622 23 650 4 2 230
50V d.c
850   150 1000 15 10  
NT6623 22.5 650 4 1 11 0 1000     1000 15 086/045839
NT6630 29.5 650 6 4 110,135
110,135
110,135
110,135
300/250
300/250
300/250
500/450
50
50
50
50
  1400 15/2
15/2
15/2
15/2
086/45840
NT6631 29.75 650 6 6 110,135
110,135
110,135
110,135
50V d.c
50V d.c
300/250
300/250
300/250
500/450
50
50
50
50
100
100
1600 15/2
15/2
15/2
15/2
10
10
086/045846
NT6650 20 650 6 2 110
110,140
110 750
(1400 intermi
ttent)
  850 5
15
086/045841
NT6660 47 650 6 1 230 3000     3000 16  
NT6661 47 650 6 1 110 3000     3000 32 086/045842

Note 1 Rating of main and subsidiary taps.

Where the rating of main taps is shown as xxx/yyy –

  • The lower rating (yyy) of the main secondary tap is used if the 135V tap is loaded with its rated load.
  • The higher rating (xxx) may be used on the main tap if the 135V tap is not used.
  • The available rating on the main tap is xxx-yyy if part load is used on the 135V tap

NT6650 intermittent rating is for direct driving of points machines. Refer to NT66XX 3.1.1 for points machine type and load conditions.

Note 2 Max fuse rating on secondary.

The Output fuse rating in table 1 is for close short circuit protection only.
Refer to the product data sheet for application data on load fuse clearance (NT66XX table 4.1.1 note 2).
The two fuse values specified are the respective values for a winding providing 110V and 135V. e.g. for NT6610 the 110V fuse maximum size is
15A and the 135V tap fuse size tap is 2A. For NT6600 the 110V fuse maximum size is 5A and the 135V tap fuse size tap is 2A.
Where the load is completely within a suite of location cases there should be no fuse between the 110V winding and the 110V busbar.
Each outgoing way on the busbar should be fused for the individual load, often 3A or 1A.

Note 3

BS88 fuses are used above 15A rating or above 250V. BS1361 or BS88 fuses are used on 230V 110V fuse range is Littlefuse 326.XXX range up to 15A.

Note 4

50V d.c. output is full wave rectified unsmoothed is expressed as “mean d.c.”

  • The rating is expressed as VA where 1VA = 1 Watt at nominal voltage.
  • Where an external smoothing capacitor is fitted to a 50V d.c. output the smoothed voltage will be approximately 70V depending on the design of the smoothing circuit.
  • Where external smoothing circuits are used the rating of the d.c. output will be reduced by 50%, e.g. a 150V winding will be rated at 75 VA for smoothed d.c.

Note 5

The total power drawn from all windings simultaneously must not exceed the total power capability of the transformer (Total VA) e.g. NT6110 can supply up to 400VA on the 110V a.c. output and up to 200VA on the 50V d.c. output.

  • However Total load on NT6610 must not exceed 500VA.
  • Thus NT6610 capacity -
    • 300VA at 110V can be supplied at the same time as 200VA at 50V
    • OR
    • 400VA at 110V can be supplied at the same time as 100VA at 50V.

The outputs of multiple windings should not be connected in parallel as this will cause circulating currents that will change the thermal performance of the transformer and potentially affect reliability. NT6612, NT6623 or NT6661 should be specified if a larger single load is required than available from the multiple winding transformers. It is recommended that loads greater than 3KVA are split and more than one transformer used.

NQ66XX Transformer Rectifiers

NQ66XX Transformer Rectifiers

Transformer/Rectifier for relay and SSI signalling systems 650V/230V/120Vd.c.

Signalling Transformer/Rectifiers provide the interface between a 650V or 230V power system and 120Vd.c. points machines. Versions are available for multiple 120V points machines. The number of points machines that can be driven by one transformer/rectifier depends on the transformer/rectifier part number chosen and the type of point machine.

The construction of the transformer in the transformer/rectifier allows system compliance with Electricity at Works Regulations and NR/SP/ELP/27243. The internal transformer complies with NR/L2/SIG/30007.

The internal transformers provide 8kV minimum impulse withstand voltage in compliance with BS7671 to provide additional protection against ground potential rise in areas with d.c. or a.c. traction systems.

Table 2

  Input Output  
      Quantity of Point machines    
Part no. KG Voltage V (1 phase unless shown) BS88 Fuse A (note2) Voltage HW Hy-Drive HPSS Max BS88 (S) Fuse A (note 1) PADS Catalogue Number
NQ6620 23 650 6 120V d.c. 2 1 2 50 086/045847
NQ6621 23 230 16 120V d.c. 2 1 2 50  
NQ6640 32 650 10 120V d.c. 4 3 4 75 086/045848

Note 1 Max fuse rating on output

The fuse rating specified is for short circuit protection only. Refer note 2.
Short circuit protection must be provided by output fuses on individual points loads when more than one point machine is driven by any rectifier and always for NQ6640.
Individual points machines must be separately fused with Littlefuse 326.XXX < 15A or equivalent.
BS88 (S) semiconductor fuses (table 2 note 1) are not required if the fuse protecting the individual points machine (Littlefuse 326.XXX < 15A) is located in the same location case or REB as the transformer/rectifier.
BS88 part 4 – 1976, IEC 269 – 4 (semiconductor fuses) are required in the output if a single cable takes 120V d.c. outside the enclosure housing the transformer/rectifier for remote distribution using Littlefuse 326.XXX range up to 15A.
Short circuit protection may be provided by primary fuses on NQ6620 and NQ6621 if only one points machine is driven. In this case 120V secondary fuse need not be fitted.
The loop impedance of the transformer/rectifier system, including the cables to the points machines shall be designed to allow more than 100A to flow in the event of a short circuit at the most remote points machine.

Note 2 Fuse type - Input

BS88 fuses are used for ratings above 15A or above 250V. BS1361 or BS88 fuses are used on 230V.